Circuit Protection Devices
Introduction
Protection of circuits and products against overload, overheating, and transient conditions becomes more important considering safety aspects and the sensitive nature of many IC components. Selecting and fitting appropriate protection devices can avoid unnecessary service calls and protect sensitive components.
We offer components to suit a variety of applications. These products are generally approved to the relevant safety standards. See the PDF data sheets for more information.
Manual Reset NP Series
NP Series circuit breakers are small size, single pole overload circuit protectors. They use a spring action and bimetal element to sense a current overload. The bimetal element responds to an overload by opening the electrical contacts. It remains open until the reset button is pushed, thereby closing the electrical contacts and reenergizing the circuit.
NPN type without mounting bush, (PCB mount).
NPS type with 5/16 x 32 threaded bush.
Applications
All kinds of electrical and electronic equipment where overload protection is needed and reset by the user is required. e.g. small appliance, motorized equipment, low power heating equipment, speakers.
Technical Data
- Current rating: 0.3 A to 12 A,, (resistive and inductive load).
- Max voltage rating: AC 250 V, DC 28 V.
- Insulation resistance: >100 MW, (DC 500 V).
- Typical life at rated current: >10000 operations.
- Shock: 30 G (11ms), to IEC 68-2-27, test Ea.
- Vibration: 8 G (57 to 500 Hz/ ± 0.61mm, 10 to 57 Hz), to IEC 68-2-6 test Fc.
- Corrosion: 96 hours at 5% salt spray, to IEC 68-2-11, test Ka.
- Humidity: 240 hours at 95% RH to IEC 68-2-3, test Ca.
- Weight: approximately 2.8 g.
See the PDF datasheet for more technical details: NP series 0.3 A to 12 A![]()
| Type NPN or NPS | Rated Hold AC at 25°C (A) | Max (V) | Trip Time 200% Current | Trip Time 300% Current | Internal Resistance (Ω) Under | Max. Interrupt Current (A) |
|---|---|---|---|---|---|---|
| NP-3 | 0.3 | 250 | 15 sec | 4 sec | 0.8 | 4 |
| NP-4 | 0.4 | 250 | 15 sec | 4 sec | 0.8 | 4 |
| NP-5 | 0.5 | 250 | 15 sec | 4 sec | 0.75 | 6 |
| NP-6 | 0.6 | 250 | 15 sec | 4 sec | 0.75 | 6 |
| NP-7 | 0.7 | 250 | 15 sec | 4 sec | 0.6 | 10 |
| NP-8 | 0.85 | 250 | 15 sec | 4 sec | 0.6 | 10 |
NP-10 |
1.0 | 250 | 15 sec | 4 sec | 0.15 | 20 |
| NP-12 | 1.25 | 250 | 15 sec | 4 sec | 0.15 | 20 |
| NP-14 | 1.4 | 250 | 15 sec | 4 sec | 0.15 | 20 |
| NP-15 | 1.5 | 250 | 15 sec | 4 sec | 0.15 | 30 |
| NP-16 | 1.6 | 250 | 15 sec | 4 sec | 0.12 | 30 |
| NP-17 | 1.75 | 250 | 15 sec | 4 sec | 0.12 | 30 |
| NP-19 | 1.9 | 250 | 15 sec | 4 sec | 0.12 | 30 |
| NP-20 | 2.0 | 250 | 15 sec | 4 sec | 0.12 | 30 |
| NP-22 | 2.2 | 250 | 15 sec | 4 sec | 0.1 | 30 |
| NP-25 | 2.5 | 250 | 15 sec | 4 sec | 0.1 | 30 |
| NP-27 | 2.7 | 250 | 15 sec | 4 sec | 0.08 | 30 |
| NP-30 | 3.0 | 250 | 15 sec | 4 sec | 0.08 | 30 |
| NP-40 | 4.0 | 250 | 15 sec | 4 sec | 0.06 | 40 |
| NP-50 | 5.0 | 250 | 15 sec | 4 sec | 0.06 | 50 |
| NP-60 | 6.0 | 250 | 15 sec | 4 sec | 0.06 | 60 |
| NP-70 | 7.0 | 250 | 15 sec | 4 sec | 0.04 | 70 |
| NP-80 | 8.0 | 250 | 15 sec | 4 sec | 0.04 | 80 |
| NP-90 | 9.0 | 250 | 15 sec | 4 sec | 0.04 | 90 |
| NP-100 | 10.0 | 250 | 15 sec | 4 sec | 0.02 | 100 |
NP-120 |
12.0 | 250 | 15 sec | 4 sec | 0.02 | 120 |
Manual Reset A-0709 Series
Mounting options - with nut (U type), snap-in (W type).
Applications
Power supply, amplifier, UPS, regulator, generator.
Specification
- Rating: 4 - 16 Amperes in 1 A steps, (13 models).
- Input power: 32 VDC / 120 VAC / 240 VAC.
- Dielectric strength: 1500 VAC / 1 min.
- Interrupt capacity 1000 A @ 120 VAC, 200 A@ 240 VAC.
- Calibration:
@ 25°C 105% of rated current - continuous.
@ 25°C 196% to 134% of rated current - may / may not trip.
@ 25°C 200% of rated current - trip within 1 minute.
e.g. 4 amp model @ 25°C 150% of rated current - trip within 60 mins. - Contact endurance: @ 120VAC / 150% of rated current - 500 cycles.
See the PDF datasheet for more technical details: A-0709 series 4 A to 16 A![]()
Manual Reset BS Series

Applications
Motors, power strips, machine tools, UPS, office equipment, power supplies.
Features
- Single or double pole ON/OFF rocker switch with protection device in a single component to avoid overload current or short circuit.
- Switch automatically returns to OFF position on overload.
- Trip free mechanism.
- Fault reminder.
- Snap-in panel mounting.
Technical Data
- Current rating: 0.3 A to 20 A, (resistive and inductive load).
- Max voltage rating: AC 250 V, DC 28 V.
- Insulation resistance: >100 MW, (DC 500 V).
- Typical life at rated current: >10000 operations.
- Minimum contact gap: 2.5 mm.
- Shock: 30 G (11ms), to IEC 68-2-27, test Ea.
- Vibration: 8 G (57 to 500 Hz/ ± 0.61 mm, 10 to 57 Hz), to IEC 68-2-6 test Fc.
- Corrosion: 96 hours at 5% salt spray, to IEC 68-2-11, test Ka.
- Humidity: 240 hours at 95% RH to IEC 68-2-3, test Ca.
- Weight: approximately 10.6 g
Other versions
- Versions with LED or neon illumination.
- Short terminals (6.6mm long).
- Round profile rocker.
- Double pole version with overload, short circuit and earth ground leakage protection.
- Magnetic factors of 4x and 7x rating.
- Double pole with thermal magnetic x7 device.
See the PDF datasheet for more technical details: BS series 0.3 A to 20 A![]()
Auto Reset AN Series

These compact overcurrent protectors are designed to protect audio speaker systems, amplifiers and power supplies from internal overcurrents. They are available up to 12 amps.
Features
- High current accuracy *.
- Protection against excessive temperature.
- Snap action.
- Automatic reset type.
- Long life.
- PBT resin enclosure.
- Economically priced.
- Reliable.
- Two mounting options.
* Low current models should be used within following maximum ambient temperatures:
- AN-04: 50°C
- AN-05: 50°C
- AN-06: 60°C
- AN-08: 70°C
Note: Rated hold current decreases with temperature >25°C, and increases with temperature <25°C.
See the PDF datasheet for more technical details: AN series 0.4 A to 12 A![]()
| Type 1: PC | Type 2: Tags | Rated Hold AC Current at 25°C (A) | Maximum Voltage (V) | Trip Time 200% Current | Trip Time 300% Current | Internal Resistance (mΩ) Under | Maximum Interrupt Current (A) |
|---|---|---|---|---|---|---|---|
| AN-041 | - | 0.4 | 250 | < 30 sec | < 5 sec | < 700 | 4 |
| AN-051 | - | 0.5 | 250 | < 30 sec | < 5 sec | < 600 | 5 |
| AN-061 | - | 0.6 | 250 | < 30 sec | < 5 sec | < 500 | 6 |
| AN-081 | - | 0.85 | 250 | < 30 sec | < 5 sec | < 500 | 10 |
| AN-101 | AN-102 | 1.0 | 250 | < 30 sec | < 5 sec | < 150 | 20 |
| AN-121 | AN-122 | 1.25 | 250 | < 30 sec | < 5 sec | < 150 | 20 |
| AN-141 | AN-142 | 1.4 | 250 | < 30 sec | < 5 sec | < 100 | 20 |
| AN-161 | AN-162 | 1.6 | 250 | < 30 sec | < 5 sec | < 100 | 20 |
| AN-171 | AN-172 | 1.75 | 250 | < 30 sec | < 5 sec | < 100 | 20 |
| AN-191 | AN-192 | 1.9 | 250 | < 30 sec | < 5 sec | < 75 | 20 |
| AN-221 | AN-222 | 2.2 | 250 | < 30 sec | < 5 sec | < 75 | 20 |
| AN-251 | AN-252 | 2.5 | 250 | < 30 sec | < 5 sec | < 75 | 25 |
| AN-271 | AN-272 | 2.7 | 250 | < 30 sec | < 5 sec | < 75 | 25 |
| AN-301 | AN-302 | 3.0 | 250 | < 30 sec | < 5 sec | < 35 | 30 |
| AN-401 | AN-402 | 4.0 | 250 | < 30 sec | < 5 sec | < 35 | 40 |
AN-501 |
AN-502 | 5.0 | 250 | < 30 sec | < 5 sec | < 30 | 50 |
| AN-601 | AN-602 | 6.0 | 250 | < 30 sec | < 5 sec | < 30 | 60 |
| AN-701 | AN-702 | 7.0 | 250 | < 30 sec | < 5 sec | < 30 | 60 |
AN-801 |
AN-802 | 8.0 | 250 | < 30 sec | < 5 sec | < 30 | 60 |
| AN-901 | AN-802 | 9.0 | 250 | < 30 sec | < 5 sec | < 30 | 60 |
| AN-1001 | AN-1002 | 10.0 | 250 | < 30 sec | < 5 sec | < 30 | 60 |
| AN-1201 | AN-1202 | 12.0 | 250 | < 30 sec | < 5 sec | < 30 | 60 |
Auto Reset TS/1 Thermostats

Supplied with two silicon wires and fully enclosed in a shrink sleeve, (case is live. hot.) Order by TS/1 (temperature rating).
Applications
Battery Pack, small domestic appliances, transformer, lighting ballast.
Features
- Rated: (resistive load)
24 VDC 100 mA. 50K+ cycles
120 VAC 10A. 10K+ cycles
120 VAC 6A. 30K+ cycles
240 VAC 6A. 10K+ cycles - Temperature: 12 versions.
- Operating tolerance: Standard ±5°C.
- Reset differential: 10° to 40°.
- Contacts: Current carrying normally closed. Snap action, quick make / break.
- Interrupt capacity: 120 VAC - 60A. 5 cycles.
- Overshoot temperature: 200°C / 3 minutes.
- Dielectric strength: 1500 VAC / minute.
- Ballast rated: 10,000 cycles.
- Weight: 5 grams (with wires).
- ISO 9002
| Part Number | Rated Temperature °C | UL Approval E 125871(S) |
|---|---|---|
| FC 672701 | 45 | √ |
| FC 672702 | 60 | √ |
| FC 672703 | 70 | √ |
| FC 672704 | 80 | √ |
| FC 672705 | 85 | √ |
| FC 672706 | 90 | √ |
| FC 672707 | 95 | √ |
| FC 672708 | 100 | √ |
| FC 672709 | 110 | √ |
| FC 672710 | 120 | √ |
| FC 672711 | 130 | |
| FC 672712 | 140 |

The PDF datasheet has the technical details: TS/1 Thermostats 45° to 140°![]()
Please contact Cliff™ sales for more information.
Our site uses PDF (portable document format) files to store information on our products. To view these files you should have a PDF reader installed. You can download Adobe Reader for free.